Specification
Description |
Abbr. |
Formulation |
Tolerance |
P=0.5 |
P=1.0 |
P=1.25 |
P=2.54 |
Pitch |
P |
Typical |
|
|
|
|
Total pitch |
Pt |
Px(n-1) |
Width |
W |
Px(n+1) |
Margin |
M |
P-(Cwx1/2) |
Conduct Width |
Cw |
Typical |
0.3 |
0.6 |
0.8 |
1.27 |
Conduct Thickness |
Ct |
Typical |
0.1 0.05 0.035 |
Total (Cable) Length |
L |
Typical |
Over 30 |
Strip Length |
S1/S2 |
Typical |
3/4/5/6 |
Support Tape Length |
S3/S4 |
Typical |
6/8/10/12/15 |
Terminal Thickness |
T |
Typical |
0.3 |
Unit: mm n:numbers of conductor

Ordering Information

Components |
Raw Material |
|
| 1 |
Conductor |
Tin plated Copper flat
conductor
Tin plating thickness: 1~3 |
| 2 |
Insulation |
polyester (PET) film + polyester (PET)
adhesive |
| 3 |
Supporting tape |
Polyester (PET) film +
polyester (PET) adhesive |
Characteristic
Item |
Test Method |
Requirement |
| 1 |
Conductor
Resistance |
JIS C-3102 |
Ct |
|
0.1 |
0.05 |
0.035 |
| Cw |
1.27 |
Less than 0.21 /m |
Less than 0.42 /m |
Less than 0.57 /m |
| 0.8 |
0.26 /m |
0.52 /m |
0.74 /m |
| 0.6 |
0.38 /m |
0.58 /m |
0.82 /m |
| 0.5 |
0.42 /m |
0.81 /m |
1.15 /m |
| 0.3 |
0.68 /m |
1.36 /m |
1.82 /m |
| 2 |
Insulation Resistance |
DC 500V after 1min. |
More than 1,000 M /m |
| 3 |
Dielectric Strength |
AC 500V for 1min. |
No breakdown |
| 4 |
Open/Short Test |
Tester, DC 3.0V, 0.1mA |
Pass |
| 5 |
Heat Resistance |
85°C, 96hrs |
Insulation Resistance and Dielectric Strength Pass |
| 6 |
Heat Cycle Test |
-40°C + 25°C--> +85°C +25°C, 12hrsx2cycle |
Insulation Resistance and Dielectric Strength Pass |
| 7 |
Moisture Resistance |
40°C, 95%RH, 96hrs |
Insulation Resistance and Dielectric Strength Pass |
| 8 |
Flame Test |
UL VW-1 |
Pass |
| 9 |
Flexing Test |
10mmRx10cmx70cycle/min |
More than 30,000 cycles |
| 10 |
Bending Test (180°)
(clip the point of supporting tape) |
±90°, 600g, 0.5mmR |
More than 100cycle |
| 11 |
Abrasion Test |
Ø5mm, 600g, 60cycles/min. |
More than 10,000 cycles |
|